Virtual Connect server profiles 161

To have FCoE entries mapped to LOMs 3 and 4 on each blade in the server, you must add three extra sets

of FCoE entries, and then add the additional entries for I/O bays 1 and 2. See ports 17-24 in the figure
below.

Creating FCoE HBA connections for a BL870c i4
Referencing the previous figure, entries 1-8 would be mapped as shown. Entries 9 and 10 would then be

mapped to LOMs 3 and 4 on the first blade in the BL870c i4, entries 11-12 would be as in this example
except that they would be UNMAPPED, and entries 13-14 would be mapped to LOMs 3 and 4 on the second

blade (and the remaining entries would not be needed).

Creating iSCSI connections

In order to provision iSCSI connections, you must remove any FCoE connections assigned by default when

FlexFabric modules are present in an enclosure. If you are not going to configure FCoE connections and the

adapter does not support iSCSI and FCoE on different PFs, delete the default connections so that those port
functions are available for iSCSI.