HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 180

Advertising
background image

Virtual Connect server profiles 180

Task

Action

Add an FC SAN connection

Click Add at the bottom of the FC HBA Connections table, or right-click in the

table, and then select Add.

Delete an FCoE connection

Click the Delete link in the Action column, or click the connection to select it,

right-click to display a menu, and then click Delete.

Add an FCoE connection

Click Add at the bottom of the FCoE HBA Connections table, or right-click in
the table, and then select Add.

Enable or disable iSCSI boot or
offload

Click the pull-down arrow in the Boot Settings column and select Primary,

Secondary, USE-BIOS, or Disabled.

View or modify iSCSI boot
configuration

To modify, click on the Edit icon next to the ‘primary’ or ‘secondary’ boot
setting. When creating an iSCSI boot for the first time, after selecting Primary

or Secondary in Boot Setting, click anywhere to display the iSCSI boot

configuration page.

Change the SAN fabric
connection

Click the pull-down arrow in the FC SAN name box.

Change or disable the port speed Click the pull-down arrow in the Port Speed box.
View Fibre Channel Boot
Parameters

Select the Fibre Channel Boot Parameters checkbox.

Enable Fibre Channel Boot on a

port

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down

arrow in the SAN Boot box, and then select the boot order. Enter a valid Boot

Target name and LUN in the edit boxes.

Disable Fibre Channel Boot on a
port

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down
arrow in the SAN Boot box, and then select Disabled.

Revert to BIOS settings for Fibre

Channel Boot

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down

arrow in the SAN Boot box, and then select Use BIOS.

Change the profile bay
assignment

Click on the bay in the Connected To column, and then select the server bay
or Unassigned.

Change the FCoE connection

Click the drop-down arrow in the FC SAN name box.

Change the FCoE port speed

Click the drop-down arrow in the Port Speed name box.

Clear unsaved changes on the
screen

Click Clear.

Save changes

Click Apply.

Cancel without saving changes Click Cancel.

Assigning a server profile with FCoE connections to an HP ProLiant

BL680c G7 Server Blade

To create a server profile with FCoE connections, and then assign it to an HP ProLiant BL680c G7 Server

Blade:

1.

Be sure that the HP ProLiant BL680c G7 Server Blade is installed correctly and powered down:

a.

Click Hardware Overview in the left navigation tree to display the Enclosures View screen.

Advertising