Virtual connect documentation – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 8

Advertising
background image

Introduction 8

o

Option to disable local account access when LDAP, RADIUS, or TACACS+ authentication is

enabled

o

Increased the default VCM local user account minimum required password length

o

SNMP access security to prevent access from unauthorized management stations

SmartLink failover improvements

IGMP “NoFlood” option when IGMP snooping is enabled

Browser support:

o

Internet Explorer 8 and 9

o

Firefox 10 and 11

Firmware upgrade rollback from a previous firmware upgrade without domain deletion

VCEM compatibility:

o

If you are running VCEM 6.3.0 or earlier, you must upgrade to VCEM 6.3.1 or later to manage a
VC 3.70/3.75 domain. The 3.70/3.75 domain can be in a VCDG in 3.30 firmware mode or later.

To enable new features in VC 3.70/3.75, you must upgrade to VCEM 7.1.1 or later and upgrade

VC domains and VCDGs to 3.30 or later. VCEM 7.1.1 does not support VC versions prior to 3.30.

o

In VC 3.70/3.75, the telemetry port throughput is Enabled by default. You must do the following to
add a fresh VC 3.70/3.75 installation to your existing VCDG:

3.30-3.60 VCDG with statistics throughput disabled—Clear the Enable Throughput Statistics

checkbox on the Ethernet Settings (Advanced Settings) screen (on page

90

), or run the following

VCM CLI command:

set statistics-throughput Enabled=false

3.30-3.60 VCDG with statistics throughput enabled—Add the domain as is. No change is

required.

o

In VC 3.70/3.75, the VLAN Capacity is set to Expanded by default. You must do the following to
add a fresh VC 3.70/3.75 installation to your existing VCDG:

3.30-3.60 with Legacy VLAN VCDG—You cannot add the domain. Select a different VCDG.

3.30-3.60 with Enhanced VLAN VCDG—Add the domain as is. No change is required.

Virtual Connect documentation

The following Virtual Connect documentation is available on the Installing tab of the HP BladeSystem
Technical Resources website (

http://www.hp.com/go/bladesystem/documentation

):

HP Virtual Connect for c-Class BladeSystem User Guide
This guide provides details for the Virtual Connect GUI, including descriptions of screen contents and
steps to set up domains, profiles, networks, and storage.

HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
This guide provides hardware installation and configuration information for initial setup of a Virtual
Connect solution. The guide also provides Virtual Connect module component and LED descriptions
and guidelines for module installation and upgrades.

HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide
This guide provides information for using the Virtual Connect Command Line Interface, including use

scenarios and complete descriptions of all subcommands and managed elements.

Advertising