Configuring Throughput Statistics

Telemetry support for network devices caters to seamless operations and interoperability by providing

visibility into what is happening on the network at any given time. It offers extensive and useful detection
capabilities which can be coupled with upstream systems for analysis and trending of observed activity.
The Throughput Statistics configuration determines how often the Throughput Statistics are collected and the

supported time frame for sample collection before overwriting existing samples. When the time frame for

sample collection is reached, the oldest sample is removed to allocate room for the new sample.
Configuration changes can be made without having to enable Throughput Statistics. Applying configuration

changes when Throughput statistics is enabled clears all existing samples.
Some conditions can clear existing Throughput Statistics:

Disabling the collection of Throughput Statistics clears all existing samples.

Changing the sampling rate clears all existing samples.

Power cycling a VC-Enet module clears all Throughput Statistics samples for that module.

Collected samples are available for analysis on the Throughput Statistics screen (on page

198

), accessible

by selecting Throughput Statistics from the Tools pull-down menu.
The following table describes the available actions for changing Throughput Statistics settings.

Task

Action

Enable/disable

Select (enable) or clear (disable) the Enable Throughput Statistics checkbox.

Change sampling rate

Select a sampling rate from the Configuration list. Supported sampling rates
include:

Sample rate of 1 minute, collecting up to 5 hours of samples.

Sample rate of 2 minutes, collecting up to 10 hours of samples.

Sample rate of 3 minutes, collecting up to 15 hours of samples.

Sample rate of 4 minutes, collecting up to 20 hours of samples.

Sample rate of 5 minutes, collecting up to 25 hours of samples.

Sample rate of 1 hour, collecting up to 12.5 days of samples.

Define Ethernet Network screen

The Define Ethernet Network screen is accessible to all users with network privileges from the Define a
Network link on the Virtual Connect Manager home page or by selecting Ethernet Network on the Define