HP ProLiant DL120 G7 Server User Manual

Page 42

Advertising
background image

Hardware options installation 42

12.

Install the redundant power supply cage.

13.

Install the system board.

14.

Connect all cables previously disconnected from the system board.

15.

Route and connect power cables to the system board and the front drive cage.

16.

Install the PCIe riser cage (on page

19

).

17.

Install the air baffle (on page

20

).

18.

Install the foam air baffle from the option kit:

IMPORTANT:

Two foam air baffles are provided in the option kit. The shorter foam air baffle is

designed to be installed in servers with a four-bay LFF drive cage configuration. The longer foam
air baffle is designed to be installed in servers with an eight-bay SFF drive cage configuration.
Depending on the server configuration, be sure to install the correct foam air baffle.

o

Foam air baffle for a four-bay LFF drive cage