Installing eva and eva4400 iscsi connectivity, Eva and eva4400 iscsi connectivity installation – HP 3000 Enterprise Virtual Array User Manual

Page 43

Advertising
background image

Installation components

Option

1 mpx100 or mpx100b
1 EULA
1 SR 232 port converter
1 Quick install instructions
1 ReadMeFirst

HP StorageWorks EVA and EVA4400 iSCSI Upgrade
Option (parts list)

* 2.0m copper cables are for use in direct-connect configurations only. See

Figure 1

through

Figure

6

and

Figure 8

. Copper cables are not supported for fabric attach. Optical cables and SFPs can also

be used for direct connect configurations.

Installing EVA and EVA4400 iSCSI connectivity

Select one of the following procedures, depending on your iSCSI option.

To install the HP StorageWorks EVA or EVA4400 iSCSI option, select the appropriate installation
procedure:

Fabric attach—Reconfigure the factory-installed EVA or EVA4400 iSCSI connectivity option to

fabric attachment mode

Field direct connect—HP StorageWorks EVA or EVA4400 iSCSI connectivity option with direct

connect attachment mode

Field direct connect—HP StorageWorks EVA or EVA4400 iSCSI connectivity option with direct

connect attachment mode

Multipath direct connect—HP StorageWorks EVA or EVA4400 iSCSI upgrade option for multipath-

ing capability and direct connect attachment mode

Multipath fabric attach—HP StorageWorks EVA or EVA4400 iSCSI upgrade option with multipath-

ing capability and fabric attachment mode

Reconfiguring the factory-installed EVA or EVA4400 iSCSI connectivity option
to fabric attach mode

Figure 1

on page 23 illustrates the factory-installed EVA iSCSI connectivity option and

Figure 7

on page

26 illustrates the fabric iSCSI–Fibre Channel attachment mode configuration.

To install fabric attach:

1.

Remove the two black Fibre Channel cables connecting the mpx100/100b to the HSV controllers.

2.

Insert the SFPs into ports FC1 and FC2 on the mpx100/100b, and into an available FP port on
each HSV controller. Then insert SFPs into four of the available ports on the Fibre Channel switches.

3.

Connect one end of an orange Fibre Channel cable to the FC1 port on the mpx100/100b.
Connect the other end of the cable to any available SFP port on the Fibre Channel switch.

4.

Connect one end of an orange Fibre Channel cable to the FC2 port on the mpx100/100b.
Connect the other end of the cable to any available SFP port on the Fibre Channel switch.

5.

Connect one end of an orange Fibre Channel cable to any available port on the Fibre Channel
switch. Connect the other end of the orange Fibre Channel cable to the available port on the top
HSV controller.

6.

Connect one end of an orange Fibre Channel cable to any available port on the Fibre Channel
switch. Connect the other end of the cable to the available FP port on the bottom HSV controller.

7.

Set the HSV controller ports to fabric topology.

EVA iSCSI Connectivity User Guide

43

Advertising
This manual is related to the following products: