Starting the mpx100/100b

To start the mpx100/100b:

1.

Attach the AC power cord to the mpx100/100b and the power distribution unit (PDU). Verify
that the mpx100’s/100b's System Power LED is illuminated.
The mpx100/100b runs a self-test and begins normal operation.

2.

Verify that the Heartbeat LED is blinking (once per second) and that the Input Fault LED is not illu-
minated.

Figure 11

shows the location of the ports and LEDs on the mpx100/100b.

Figure 11 The mpx100 port and LED locations

.

2. Heartbeat LED

1. Management port (10/100 Ethernet)

4. System Fault LED

3. Input Power LED

6. iSCSI ports

5. FC ports

8. AC power

7. RS–232 port

Setting the mpx100/100b management port to use HP
StorageWorks Command View EVA

Communication between the mpx100/100b and HP Command View EVA is established through the
IP management port of the mpx100/100b and the IP connection of the HP Command View EVA
application server. This link is necessary for iSCSI device discovery and subsequent iSCSI settings of
the mpx100/100b through HP Command View EVA.

To set the mpx100/100b management port:

1.

Use Telnet to connect to the mpx100/100b management port, or connect to the mpx100/100b
serial port using the HP-supplied connector.

NOTE:

The mpx100/100b management port’s default IP address is 10.0.0.1/255.0.0.0. The
mpx100/100b serial port's default setting is 115200/8/n/1.

2.

Log in with the user name guest and the password password.