HP StorageWorks XP Remote Web Console Software User Manual

Page 100

Advertising
background image

Table 34 Cause of Error and the Result of RAID Manager Command (SSB) (continued)

Cause of Error

RAID Manager Command

SSB2

SSB1

The command ended
abnormally because the pair

All commands

9719

is in the status that the
corresponding command is
not accepted at present.

This error also may be
reported when the command
is executed with specifying
an unsupported parameter.

Since the capacity of shared
memory is insufficient, the
pair cannot be created.

paircreate

971a

Since the attribute of the
specified pool is other than

paircreate

971b

XP Snapshot, an XP
Snapshot pair cannot be
created.

Since the volume you
specified as the P-VOL has

pairresync -

restore

971f

an S-VOL Disable attribute,
an XP Snapshot pair cannot
be restored.

Any errors have occurred
because of the XP Snapshot
operation.

All commands

9720

Since either XP Snapshot or
XP Business Copy Software

paircreate

pairsplit

9721

is not installed, the
command ends abnormally.

pairresync

pairresync -

restore

Because of no additional
shared memory (FCV2, TPF,

All commands

9723

Extention1), the command
ends abnormally.

Because of no additional
shared memory (more than

All commands

9724

XP1), the command ends
abnormally.

Since the LDEV number of
the volume you specified as

All commands

9725

the P-VOL is beyond the
specified range, the
command ends abnormally.

Since you specified the
unmounted volume as the XP

All commands

9726

Snapshot P-VOL, the
command ends abnormally.

Since you specified the
blocked volume as the XP

paircreate,

pairsplit,

9727

Snapshot P-VOL, the
command ends abnormally.

pairresync,

pairresync -

pairresync -

100 Troubleshooting

Advertising