Migrating Aliases

The alias assigned to the base device must be canceled and reassigned in order to migrate it.

WARNING!

When migrating aliases, you must confirm that the number of requests to the base

device that the alias is moved from, is less then 50 IOPS by acquiring performance information
using RMF (Resource Measurement Facility Report Analysis) etc. before migrating the alias. If the
alias is migrated when there are many requests to the base device, the process performance may
decline in the worst cases.

To migrate aliases to volumes in the connected storage system:

1.

Execute step

1

to

4

of Canceling Aliases (see

“Canceling Aliases” (page 33)

).

2.

Execute step

3

of Assigning Aliases (see

“Assigning Aliases” (page 30)

).

3.

Select Apply in the Compatible PAV window. When the set Compatible PAV confirmation
dialog box appears, click OK to migrate the aliases as specified. To cancel your request, click
Cancel.

When migrating aliases included in another LDKC, change the LDKC by step

1

of

“Canceling

Aliases” (page 33)

, and then execute step

1

to

3

.

Considerations for Defining the Storage System Devices to the Host System

This section simply describes the considerations when you define the device from the host system.

The serial number of the storage system differs from the LDKC serial number which the host
recognizes per LDKC. The device address which is specified from the host differs from the LDEV
number (CU:LDEV) of the subsystem.

IMPORTANT:

For CC, the 2105 or 2107 controller emulation type cannot be intermixed with

other emulation types within the storage system. If the storage system has existing CC volumes and
you want to implement Compatible PAV, you must change to 2105 or 2107 emulation as follows:

1.

Stop all Concurrent Copy jobs.

2.

Change the DKC emulation type of all CHA packages in the storage system to I-2105 or
I-2107.

3.

Restart Concurrent Copy jobs.

Compatible PAV operations require that one SSID be set for each set of 256 LDEVs.

Defining Base and Alias Devices

The unit address mapping for base and alias devices must be defined to the host operating system
and must match the address mapping defined at the Remote Web Console computer. If the mappings
do not match, serious failures can occur during data processing.

Table 8 (page 34)

shows examples

of mappings between base devices and alias devices.

Table 8 Mapping Between Base Devices and Alias Devices

x00-x3F:Alias

(D)

x00-x7F:Alias

(C)

x00-x3F:Base

(B)

x00-x3F:Base

(A)

x40-x7F:Base

x80-xFF:Base

x40-x7F:Alias

x40-xFF:Alias

x80-xBF:Alias

x80-xBF:Base

xC0-xFF:Base

xC0-xFF:Alias

34

Performing Compatible PAV Operations