Flexiblelom option – HP ProLiant DL160 Gen8 Server User Manual
Page 63
Hardware options installation 63
14.
Connect each power cord to the server.
15.
Connect each power cord to the power source.
16.
FlexibleLOM option
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
circuitry remain active until AC power is removed.
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove any attached network cables.
4.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
5.
Remove the access panel (on page
6.
Remove the processor air baffle (on page
7.
Remove the PCI riser cage (on page
8.
Loosen the thumbscrew.
9.
Remove the FlexibleLOM blank.
10.
Install the component:
a.
Firmly seat the FlexibleLOM in the slot.