Hardware options installation 63

14.

Connect each power cord to the server.

15.

Connect each power cord to the power source.

16.

Power up the server (on page

16

).

FlexibleLOM option

WARNING:

To reduce the risk of personal injury, electric shock, or damage to the equipment,

remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal

circuitry remain active until AC power is removed.

1.

Power down the server (on page

16

).

2.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

3.

Remove any attached network cables.

4.

Do one of the following:

o

Extend the server from the rack (on page

17

).

o

Remove the server from the rack (on page

16

).

5.

Remove the access panel (on page

19

).

6.

Remove the processor air baffle (on page

20

).

7.

Remove the PCI riser cage (on page

21

).

8.

Loosen the thumbscrew.

9.

Remove the FlexibleLOM blank.

10.

Install the component:

a.

Firmly seat the FlexibleLOM in the slot.