Specifications, Environmental specifications, Server specifications – HP ProLiant DL160 Gen8 Server User Manual

Page 91: Power supply specifications

Advertising
background image

Specifications 91

Specifications

Environmental specifications

Specification

Value

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Nonoperating

-30°C to 60°C (-22°F to 140°F)

Relative humidity
(noncondensing)

Operating, maximum wet bulb

temperature of 28°C (82.4°F)

10% to 90%

Nonoperating, maximum wet
bulb temperature of 38.7°C

(101.7°F)

5% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.

Server specifications

Specification

Value

Height

4.32 cm (1.70 in)

Depth (chassis with SFF drive
cage)

69.9 cm (27.5 in)

Depth (chassis with LFF drive cage) 75.0 cm (29.5 in)
Width

43.46 cm (17.11 in)

Weight (maximum SFF: two

processors, one power supply,
eight drives)

16.9 kg (37.25 lb)

Weight (maximum LFF: two

processors, one power supply,

four drives)

17.6 kg (38.80 lb)

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:

HP 460 W CS Power Supply (94%) specifications

HP 750 W CS Power Supply (94%) specifications

HP 500 W Multi-output Power Supply specifications

HP 750 W DC CS Power Supply (94%) specifications

Advertising