Troubleshooting 38

Problem

Solution

a bootable LUN, then refer to the solutions provided in #5.

7

If Problems 1-3, and 5-6 all
fail

Use the iSCSISelect utility to erase the Controller Configuration.

From the Controller Configuration menu select Erase Configuration,
then press Enter.

A message appears asking if you want to erase the current
configuration. Press Y.

You are cautioned that the operation removes any existing
configuration permanently. Press Y.

If you have multiple controllers, erase the configuration of each controller
separately.
After you erase the Controller Configuration, reboot the system and then
reconfigure controller.

8

You get this POST error
message: "Initiator iSCSI
Name mismatch, please use
iSCSISelect to set a single
name for all controllers.
Press <Ctrl><S> to enter
iSCSISelect. (Reboot
required)"

In the iSCSI BIOS, the ServerEngines iSCSI Initiator Name may be
different if there are more than one NC-Series ServerEngines controllers in
the system. If the iSCSI Initiator name is different on multiple controllers,
you will receive a POST error message indicating an iSCSI Name
mismatch. You must enter iSCSISelect and “Save” a new initiator name on
the first iSCSISelect menu screen so that the iSCSI Initiator Name on all
controllers match. All logins from the multiple controllers use the new
name.