HP Storage Mirroring Software User Manual
Page 461

459 of 739
ID
Category
Severity
Event Message
Required Response
5107
Failover
Error
Error occurred in running
%1 script.
Verify that the script
identified exists with the
proper permissions.
5108
Failover
Error
The source machine %1 is
not responding to a ping.
This occurs when all
monitored IP addresses
on the source machine
stop responding to pings.
Countdown to failover
will begin at the first
occurrence and will
continue until the source
machine responds or
until failover occurs.
5109
Failover
Error
The public NIC on source
machine %1 is not
responding to a ping.
The failover target did
not receive an answer to
its ping of the source
machine. Eventually, a
failover will result.
Investigate possible
errors (down server,
network error, etc.).
5110
Failover
Info.
The %1 script "%2" is still
running.
No action required.
5200
Failback
Info..
Failback completed for %1. No action required.
5201
Failback
Info..
IP address %1 was
removed from target
machine's %2 adapter.
No action required.
5202
Failback
Error
Unable to Failback properly
because IP address %1
was missing a
corresponding SubNet
Mask.
Contact technical
support.
5300
Monitoring
Info.
The following IP address
was added to target's
monitoring list: %1
No action required.