System maintenance switch, System maintenance switch procedures, Clearing the system configuration – HP ProLiant BL680c G7 Server-Blade User Manual

Page 11

Advertising
background image

Component identification 11

System maintenance switch

The system maintenance switch (SW1) is an eight-position switch that is used for system configuration. The
default position for all eight positions is Off.

Position

Description

Function

S1

iLO 3 security

Off = iLO 3 security is enabled.
On = iLO 3 security is disabled.

S2

Configuration
lock

Off = System configuration can be
changed.
On = System configuration is

locked.

S3

Reserved

Reserved

S4

Reserved

Reserved

S5

Password
protection

override

Off = No function
On = Clears power-on password

and administrator password

S6

Invalidate
configuration

Off = Normal
On = Clears NVRAM

S7

Reserved

Reserved

S8

Reserved

Reserved

System maintenance switch procedures

When you perform troubleshooting steps, this guide may instruct you to perform the following procedures:

Clear the system configuration ("

Clearing the system configuration

" on page

11

).

Access the redundant ROM ("

Accessing the redundant ROM

" on page

12

).

To complete these procedures, you must change physical settings on the system maintenance switch.

Clearing the system configuration

RBSU can be used to restore the factory default configuration. For more information, see "HP ROM-Based
Setup Utility (on page

82

)." If the system is unable to boot into RBSU, use the following steps to clear the

system configuration:

1.

Power down the server blade (on page

16

).

2.

Remove the server blade (on page

17

).

3.

Remove the access panel.

4.

Change position 6 of the system maintenance switch to on.

5.

Install the access panel.

6.

Install the server blade in the enclosure and power up the server blade.

7.

Wait for the POST message that prompts you to change the switch setting:
Maintenance switch detected in the "On" position.
Power off the server and turn switch to the "Off" position.

8.

Repeat steps 1 through 3.

9.

Change position 6 of the system maintenance switch to off.