SHOW IOX STATUS

•

Command:

SHOW IOX STATUS { ALL | <iox_number> {[ - | , ] <iox_number> }}

•

Description:

Displays IO expansion enclosure status information:

◦

Status

◦

Power state of I/O bays

◦

UID state

◦

Diagnostic status

◦

Power subsystem status

◦

Cooling subsystem status

◦

Xbar Fabric status

◦

I/O slots state

◦

Thermal sensor status

•

Access level/Bay level:

OA Administrator, OA Operator, OA User

•

Restrictions:

You must be connected to the monarch OA.

•

Example:

OA-001CC414F34F> show iox status 6
IOX 6:
Health: OK
Power:
Bay 1: On
Bay 2: Off
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Redundancy OK

Power Subsystem:
Status: OK
Redundancy State: Redundant
Power Capacity: 4500 Watts DC
Power Available: 4500 Watts DC
Present Power: 247 Watts AC
PS 1: OK
PS 2: OK
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 4/4/3
Fan 1: 5486 RPM (30%)
Fan 2: 5479 RPM (30%)
Fan 3: 0 RPM (0%)
Fan 4: 5488 RPM (30%)

Xfabric Link Status:
Link 1: OK

106 IOX enclosure management commands