Set enclosure serial_number, Set enclosure uid, Set iox uid – HP Integrity Superdome 2 Server User Manual

Page 75: Set llf interval

Advertising
background image

SET ENCLOSURE SERIAL_NUMBER

•

Command:

SET ENCLOSURE SERIAL_NUMBER "<serial number>"

•

Description:

Sets the enclosure serial number.

•

Access level/Bay level:

OA Administrator

•

Restrictions:

Must be 10 characters in length and includes all alphanumeric, underscore (_), and dash (-)
characters.

SET ENCLOSURE UID

•

Command:

SET ENCLOSURE UID {ON | OFF}

•

Description:

Turns the UID LED of the enclosure on or off.

•

Access level/Bay level:

OA Administrator, OA Operator

•

Restrictions:

None

SET IOX UID

•

Command:

SET IOX UID { ALL | <iox number> [{-|,}] <iox number>]} {ON | OFF}

•

Description:

Turns the UID LED of the specified IOX enclosures on or off.

•

Access level/Bay level:

OA Administrator, OA Operator, OA user

•

Restrictions:

You must be logged on to the monarch OA to perform this command.

SET LLF INTERVAL

•

Command:

SET LLF INTERVAL <seconds>

•

Description:

Set the Link Loss Failure Interval

•

Access level/Bay level:

Operator, Administrator

•

Restrictions:

Must have OA permission to perform this command.

SET ENCLOSURE SERIAL_NUMBER

75