Set enclosure name, Set enclosure part_number, Set enclosure pdu_type – HP Integrity Superdome 2 Server User Manual

Page 74

Advertising
background image

SET ENCLOSURE NAME

•

Command:

SET ENCLOSURE NAME "<enclosure name>"

•

Description:

Changes the enclosure name.

◦

◦

The default enclosure name is the mid-plane serial number.

•

Access level/Bay level:

OA Administrator, OA Operator

•

Restrictions:

The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric,
underscore (_), and dash (-) characters.

SET ENCLOSURE PART_NUMBER

•

Command:

SET ENCLOSURE PART_NUMBER "<part number>"

•

Description:

Sets the part number of the enclosure

•

Access level/Bay level:

OA Administrator

•

Restrictions:

Must be 10 characters in length and the first character must be a digit. Acceptable characters
are all alphanumeric and the dash (-).

SET ENCLOSURE PDU_TYPE

•

Command:

SET ENCLOSURE PDU_TYPE {1|2|3|4}

•

Description:

Sets the enclosure PDU type to:

◦

1 = Single-phase

◦

2 = Three-phase

◦

3 = Three-phase, international

◦

4 = DC Power Input Module

•

Access level/Bay level:

OA Administrator

•

Restrictions:

Only 1, 2, 3, 4 are valid PDU types.

74

Enclosure management commands

Advertising