Test camnet – HP Integrity Superdome 2 Server User Manual

Page 161

Advertising
background image

Restrictions:

The <physical location> value must be formatted as either an 8–byte hexadecimal
integer, or a long or medium hardware resource path string (short form strings are not
supported).

Must be in the Health Repository viewer.

Example:

myhost HR> show 0x0100FF01FF00FF11

Location Installation/Health History - Mon May 18 16:15:45 2009
--------------------------------------------------

FRU Type: CPU Socket
Location: 0x0100FF01FF00FF11 enclosure1/blade1/socket0
Timestamp: Mon May 18 16:11:19 2009
Reason: 0x7FE1E7B03000B0C8
State: Acquitted

--- Install History 1 ---
How Found: Indictment
Timestamp: Mon May 18 16:10:38 2009
Serial Num: N/A
Parent Serial: N/A
Part Num: N/A
Who Deconfig: N/A

--- Action - Indict ---
Event No: 0x0000000000000000
Bundle ID: 0
Alert ID:
BOE Section: N/A
BOE Symptoms: 00000001
- Indicted / Acquitted -
Type Timestamp Entity Reason
Ind Mon May 18 16:10:38 2009 Human 0x0000000000000001
Acq Mon May 18 16:11:19 2009 Human User request
---
- Supporting Symptoms - No symptoms flagged.
- SubFru Isolation - Entire FRU indicted.
- SubFru Deconfiguration - No flags set.
- Related Locations - None.
- Acquittal Policy -
CAE User FRU Powr Svc FRU MFW CFW CAE Coh
req req chg cycl cycl OK unc unc unc acq
0 1 1 0 1 0 0 0 0 0
---

--- end report --- 1 records shown

TEST CAMNET

Command:

TEST CAMNET <physical location>

Description:

Performs an active test of the CAMNet manageability fabric. This test detects problems resulting
from malfunctioning hardware, missing or broken cables, or from incorrect cabling. Any test
failures results in a series of hardware indictments referencing specific hardware elements
encountering problems. To view the generated indictments, see

“SHOW INDICT” (page 159)

.

TEST CAMNET

161