Supported data path configurations – HP XP P9500 Storage User Manual

Page 26

Advertising
background image

Table 13 Link speed, maximum distance to 10 km (continued)

Maximum distance for best performance

Link speed

3 km

4 Gbps

1.5 km

8 Gbps

Your HP account team can provide the latest information on the availability of serial-channel
Continuous Access Synchronous connections.

Supported data path configurations

Three Fibre Channel configurations are supported for Continuous Access Synchronous. LUN
Manager is used to set port topology.

Direct connection—two devices are connected directly together, shown below.

Figure 6 Direct connection

Set port topology to: Fab off, FC-AL.

Switch connection—up to three optical fibre cables are connected using switches. Up to two
switches can be used, as shown below.

Figure 7 Switch connection

Set port topology to the following:

NL port: Fab on, FC-AL

N port: Fab on, Point-to-Point

Some switch vendors require F port (for example, McData ED5000).

Extender connection—channel extenders and switches are used to connect the devices across
large distances, as shown below.

Figure 8 Extender connection

26

Planning for Continuous Access Synchronous

Advertising