Network Storage Controller Status

•

Transfer/Sec—The average number of transfers (reads and writes) on this network storage
controller each second

•

MBytes/Sec—The average number of megabytes transferred on this network storage controller
each second

•

Millisec/Transfer—The average time to complete a transfer to and from the selected network
storage controller

•

Queue Length—The average number of transfer requests (reads and writes) waiting to be
serviced by the network storage controller

•

Port Utilization%—The average utilization of the Fibre Channel port on this controller Network
Storage Controller Inventory

Network Storage Controller Inventory

Controller Configuration

•

The controller identification, including controller model

•

The supported and negotiated PCI protocols (bus speed)

Network storage array

The following information is provided for a network storage array.

Network Storage Array Status

•

Server Transfers/Sec—The average number of transfer requests (read and written) between
the monitored servers and the array each second

•

Server MBytes/Sec—The average number of megabytes transferred (read and written) between
the monitored servers and this array each second

•

Server Millisec/Transfer—The average time for each request between the monitored servers
and the array to complete

•

Server Queue Length—The average number of transfer requests (read and written) from the
monitored servers that are waiting to be serviced by this array

•

Array MBytes/Sec—The average number of megabytes transferred (read and written) to all
the disks in the array each second

•

Disk Queue Length—The average number of transfer requests (read and written) waiting to
be serviced by each disk in the array

Network Storage Array Inventory

•

Array Configuration—Displays the number of logical drives implemented on the array

•

Hard Drives—Lists the drives that constitute the array

Network storage logical drives

The following information is provided for logical drives located in the network storage.

Network Share Status

•

Reads/Sec—The average number of reads from the selected logical drive each second

•

Writes/Sec—The average number of writes to the selected logical drive each second

•

Read MBytes/Sec—The average number of megabytes read from the selected logical drive
each second

•

Write MBytes/Sec—The average number of megabytes written to the selected logical drive
each second

Network storage array