What if LUN 0 is on disks in the enclosure?
If any of the disks in the enclosure are part of LUN 0, you will not be able to
unbind the LUN before moving the disks. Instead, you must replace LUN 0 and
exclude any of the disks in the enclosures from LUN 0.
4. Power down the disk array, both the array controller enclosure and the disk enclosures.
5. Remove the disk enclosures from the rack. To remove the enclosures, reverse the steps
listed in
"Installing the Disk Enclosures" on page 160
6. Install the disk enclosures in the new rack following the instructions in
. Make sure the disk enclosure is configured properly for
the new disk array.
7. Bind a LUN with the new disks using the management tool of your choice:
– To use SAM, see
– To use Array Manager 60, see
– To use STM, see
Note
After binding a LUN, you must execute the
insf -e
command to install special
device files on the LUN. This makes the LUN usable by the operating system.