Raid level comparisons – HP Surestore Disk Array 12h and FC60 User Manual
Page 57

Disk Array High Availability Features 57
Produ
ct Des
c
ript
ion
RAID Level Comparisons
To help you decide which RAID level to select for a LUN, the following tables compare the
characteristics for the supported RAID levels. Where appropriate, the relative strengths
and weakness of each RAID level are noted.
Note
RAID 3 is supported on Windows NT and Windows 2000 only.
Table 1
RAID Level Comparison: Data Redundancy Characteristics
RAID Level
Disk Striping
Mirroring
Parity
Handle multiple disk
failures?
RAID 0
Yes
No
No
No. RAID 0 offers no data
redundancy or protection
against disk failure. RAID 0
should only be used for non-
critical data. The failure of a
single disk in a RAID 0 LUN
will result in the loss of all
data on the LUN.
RAID 1
No
Yes
No
No
RAID 0/1
Yes
Yes
No
Yes, providing both disks in
a mirrored pair do not fail.
RAID 3
Yes
No
Yes
No
RAID 5
Yes
No
Yes
No