HP Surestore Disk Array 12h and FC60 User Manual
Page 323

Status Conditions and Sense Code Information 323
M
a
na
ging
the
Di
sk
Array
on HP-UX
0x08
Disk Enclosure Group - comprises attached disk enclosures. This group
includes the power supplies, environmental monitor, and other
components in the disk enclosure. See
for information on identifying component
and status.
0x09-0x0F
Reserved
0x10-0xFF
Drive Groups - comprises a drive (embedded controller, drive electronics,
and Head Disk Assembly), its power supply, and the SCSI cable that
connects it to the controller; or supporting sub-enclosure environmental
electronics. The FRU code designates the channel ID in the most
significant nibble and the SCSI ID of the drive in the least significant
nibble.
NOTE: Channel ID 0 is not used because a failure of drive ID 0 on this
channel would cause an FRU code of 0x00, which the SCSI-2 standard
defines as no specific unit has been identified to have failed or that the
data is not available.
Table 43
FRU Code Groups
FRU Code Value
Group Description