HP Surestore Disk Array 12h and FC60 User Manual
Page 364

364 Introduction
•
Probable Cause/Recommended Action – The cause of the event and suggested steps
toward a solution. This information should be the first step in troubleshooting.
Figure 91
Sample EMS Hardware Event Notification Message
Notification Time: Thu Aug 6 15:18:03 1998
yourserver sent Event Monitor notification information:
/peripherals/events/mass_storage/LVD/enclosure/10_12.8.0.255.0.10.0 is
!=1.
Its current value is CRITICAL(5)
Event data from monitor:
Event Time: Thu Aug 6 15:18:03 1998
Hostname: yourserver.rose.hp.com IP Address: 15.43.212.175
Event ID: 0x0035ca2b9b00000002 Monitor: dm_ses_enclosure
Event # : 101 Event Class: I/O
Severity: Critical
Enclosure at hardware path 10/12.8.0.255.0.10.0: Hardware failure
Associated OS error log entry id(s): None
Description of Error:
The disk device is indicating a fault.
Probable Cause/Recommended Action:
The disk drive in slot 1 has failed. Check the connection, reseat,
or replace the disk drive.