Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in

the controller firmware and the operating system driver.

•

Unknown—Indicates that the Storage Agents cannot determine the redundancy type for the controller. You

may need to upgrade the Storage Agents.

•

Redundancy Error—Displays the redundancy error for the controller. The following values are valid:

•

No Failure—No failures have been detected.

•

No Redundant Controller—No redundant controller is installed.

•

Different Hardware—The other controller indicates a different hardware model.

•

No Link—A link to the other controller could not be established.

•

Different Firmware—The other controller indicates a different firmware version.

•

Different Cache—The other controller indicates a different cache size.

•

Other Cache Failure—The other controller indicates a cache failure.

•

No Drives—This controller cannot see any attached drives, but the other controller can.

•

Other No Drives—This controller can see the attached drives, but the other controller cannot.

•

Unsupported Drives—One or more attached drives has been determined to be incapable of properly

supporting redundant controller operation.

•

Expand in Progress—An expand operation is in progress. Redundant operation not supported until the

expand operation is complete.

•

Unknown—Indicates that the Storage Agents are unable to determine the redundancy error for the

controller. You may need to upgrade the Storage Agents.

•

Firmware Version—L

ists the firmware version of the array controller. This value can be used to help

identify a particular revision of the controller.

•

Product Revision—Displays the revision of the array controller board. This value can be used to help identify a

particular revision of the controller.

•

Serial Number—Displays the serial number for the array controller. Use this number for identification purposes.

•

Processor Usage—Displays the total percentage of the processor usage, expressed as a number from 0 to 100

inclusive.

•

Command Count—Displays the total number of read and write commands processed in this sample. This value

is expressed as read and write commands per second.

•

Command Latency—Displays the average command latency for this sample in 1/100,000 of a second units.

•

ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The module enables

advanced controller features such as Advanced Data Guarding. The following values are valid:

•

Not Supported—Indicates that the RAID ADG Enabler Module is not supported by this type of controller.

•

Not Present—Indicates that the RAID ADG Enabler Module is not present or is not accessible.

•

Fully Functional—Indicates that the RAID ADG Enabler Module is functional and accessible.

•

Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.

•

Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.

•

Present - Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed, but a firmware

upgrade is required to make it fully functional.

•

Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler Module. You may

need to upgrade the Storage Agents.

•

Daughter Board Type—D

isplays the type of daughter board installed on the array controller. The

following values are valid:

•

Not Supported—Indicates that the array controller does not support daughter boards or it does not support

daughter board identification.

•

Not Present—Indicates that a daughter board is not installed on the array controller.

•

SCSI—Indicates that a SCSI daughter board is installed on the array controller.

•

Fibre—Indicates that a Fibre daughter board is installed on the array controller.

•

Array—Indicates that an Array Expansion Module is installed on the array controller.

•

Unknown—Indicates that the daughter board type is not recognized. You may need to upgrade the Storage

Agents.

•

Rebuild Priority—D

isplays the logical drive rebuild priority of the controller. The following values are

valid:

•

Low—Indicates the rebuild priority is low.

•

Medium—Indicates the rebuild priority is medium.