Tape devices – HP Insight Management Agents User Manual

Page 59

Advertising
background image

Agent information 59


•

Degraded—Indicates that the library has degraded in some manner.

•

Failed—Indicates that the library has failed and can no longer return data. The library might need to be

replaced.

•

Offline—Indicates that the Storage Agents can no longer communicate with the library. This could be

caused by a cabling problem or the library might be powered off.

•

Unknown—The status of the tape library cannot be determined. Ensure the latest drivers and Storage Agents

are installed.

•

Model—Displays the tape library model.

•

Serial Number—Displays the unit serial number for the library. It can be used for identification purposes.

•

Firmware Version—Displays the firmware revision level of the tape library as returned by the SCSI inquiry

command.

•

Service Hours—Displays the number of hours in service.

•

Total Moves—Displays the total number of moves.

•

Door Status—Displays the tape library door status. The following values are valid:

•

Open—Indicates that the tape library door is open.

•

Closed—Indicates that the tape library is closed.

•

Not supported—Indicates that the tape library does not detect or report door status.

•

Unknown—The door status of the tape library cannot be determined. Ensure the latest drivers and Storage

Agents are installed.

•

Temperature—Displays the tape library temperature status. The following values are valid:

•

OK—Indicates that the temperature of the library is within normal operating limits.

•

Safe Temperature Exceeded—Indicates that the temperature of the library has exceeded the safe operational

temperature. The library continues to operate under this warning.

•

Maximum Temperature Exceeded—Indicates that the temperature of the library has exceeded the normal

operating limits to the extent that the library might no longer function.

•

Not supported—Indicates that the library cannot detect or report the temperature status.

•

Unknown—The temperature status of the tape library cannot be determined. Ensure the latest drivers and

Storage Agents are installed.

•

Redundancy—Displays the tape library redundancy status, which denotes the presence of internal redundant

components, such as fans, power supplies, etc. The following values are valid:

•

Active—Indicates that the library is capable of detecting and reporting redundant components, there are

enough redundant units already installed, and the redundancy is active.

•

Capable—Indicates that the library is capable of detecting and reporting redundant components but there

are not enough redundant units installed to make redundancy active.

•

Not capable—Indicates that the library is capable of detecting and reporting redundant components but

there are no components that support redundancy.

•

Not supported—Indicates that the library cannot detect or report redundancy status.

•

Unknown—The redundancy status of the tape library cannot be determined. Ensure the latest drivers and

Storage Agents are installed.

•

Hot Swap—Displays the tape library hot swap status which denotes the presence of hot swappable internal

components, such as drives, fans, power supplies, etc. The following values are valid:

•

Capable—Indicates that the library is capable of detecting and reporting hot-swappable internal

components and has at least one hot-swappable component.

•

Not capable—Indicates that the library is capable of detecting and reporting hot swappable internal

components but there are no hot-swappable components installed.

•

Not supported—Indicates that the library cannot detect or report hot-swap status.

•

Unknown—The hot-swap status of the tape library cannot be determined. Ensure the latest drivers and

Storage Agents are installed.

•

Last Known Error—Displays the hexadecimal error status code including text information, if available. For

details, see the hardware documentation for more information.

•

Associated Tape Drives—Displays a list of tape drives associated with the tape storage system.

Tape devices

Select a tape device entry in the SCSI controller submenu to display a list of information and status associated with

the selected tape device. The following information is displayed:

•

Status—Displays the status of the SCSI Tape drive that you selected. The following values are valid: