Continuous access synchronous z, Continuous access journal z – HP XP P9500 Storage User Manual

Page 30

Advertising
background image

Condition

Operation name

Release pairs

The specified LDEVs must be assigned to the Storage Administrator group permitted
to manage them.

Set reserve attributes

Remove reserve attributes

Continuous Access Synchronous Z

The following table provides information about specific Continuous Access Synchronous Z conditions
that must be observed when using Resource Partition.

Condition

Operation name

M-VOLs must be assigned to the Storage Administrator group permitted to manage
them.

Create pairs

Initiator ports for the logical paths that are configured between M-VOLs and RCU
must be assigned to the Storage Administrator group permitted to manage them.

M-VOLs must be assigned to the Storage Administrator group permitted to manage
them.

Change pair options

The specified M-VOLs or R-VOLs must be assigned to the Storage Administrator
group permitted to manage them.

Split pairs

M-VOLs must be assigned to the Storage Administrator group permitted to manage
them.

Resynchronize pairs

The specified M-VOLs or R-VOLs must be assigned to the Storage Administrator
group permitted to manage them.

Release pairs

When you specify M-VOLs, initiator ports for the logical paths that are configured
between M-VOLs and RCU must be assigned to the Storage Administrator group
permitted to manage them.

The specified ports must be assigned to the Storage Administrator group permitted
to manage them.

Define port attributes

The specified initiator ports must be assigned to the Storage Administrator group
permitted to manage them.

Add RCUs

Initiator ports of logical paths to the specified RCUs must be assigned to the Storage
Administrator group permitted to manage them.

Delete RCUs

Change RCU options

The specified initiator ports must be assigned to the Storage Administrator group
permitted to manage them.

Add logical paths

Delete logical paths

Initiator ports of logical paths to the specified RCUs must be assigned to the Storage
Administrator group permitted to manage them.

Add SSIDs

Delete SSIDs

Continuous Access Journal Z

The following table provides information about specific Continuous Access Journal Z conditions
that must be observed when using Resource Partition.

Condition

Operation name

All the LDEVs that are specified when creating a journal must belong to the same
resource group.

Create journal volumes

All the specified LDEVs when adding journal volumes must belong to the same
resource group where existing journal volumes belong.

Add journal volumes

Delete journal volumes

30

Configuring resource groups