Calculating the size of a CV using Enhanced mode on SATA drives

If the data protection level is set to Enhanced mode on a SATA drive, the entire capacity of a CV
must be calculated based on the previously calculated entire capacity of a CV. The calculation
methods vary depending on the unit for the capacity specified when creating the CV.

If the CV capacity unit is MB (megabytes):

To calculate the entire capacity of a CV whose capacity unit is defined as MB:

entire-capacity-of-a-CV * 1024 / capacity-of-a-slot

where

capacity-of-a-slot

is expressed in kilobytes. The capacity of a slot depends on volume

emulation types (see

“Capacity of a slot” (page 40)

).

The resulting entire capacity is expressed in slots.

To calculate the management area capacity:

ceil(entire-capacity-of-a-CV(slots) /
calculated-management-area-capacity) * boundary-value

where

the value enclosed in ceil( ) must be rounded up to the nearest whole number.

The resulting entire capacity is expressed in slots.

To calculate the entire capacity of a CV if the data protection level is set to the Enhanced mode
on the SATA drive:

ceil(entire-capacity-of-a-CV(slots) + calculated-management-area-capacity)

To convert the resulting entire capacity into megabytes:

calculated-entire-capacity-of-a-CV(slots) /
1024 * capacity-of-a-slot

where

calculated-entire-capacity-of-a-CV(slots)

means the entire capacity of a CV

if the data protection level is set to the Enhanced mode on the SATA drive.

If the CV capacity unit is block:

To calculate the entire capacity of a CV whose capacity unit is defined as block:

user-specified-a-CV-capacity / 2 / capacity-of-a-slot

where

capacity-of-a-slot

is expressed in kilobytes. The capacity of a slot depends on volume

emulation types (see

“Capacity of a slot” (page 40)

).

The resulting entire capacity is expressed in slots.

To calculate the management area capacity:

ceil(entire-capacity-of-a-CV(slots) /
calculated-management-area-capacity) * boundary-value

where

the value enclosed in ceil( ) must be rounded up to the nearest whole number.

To calculate the entire capacity of a CV if the data protection level is set to the Enhanced mode
on the SATA drive:

ceil(entire-capacity-of-a-CV(slots) + calculated-management-area-capacity)

To convert the resulting entire capacity into blocks:

calculated-entire-capacity-of-a-CV(slots) * capacity-of-a-slot * 2