BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT

³

Save these instructions for

local inspector’s use.

IMPORTANT

³

Observe all governing codes

and ordinances.

Note to Installer

³

Be sure to leave these

instructions with the Consumer.

Note to Consumer

³

Keep these instructions

with your Owner’s Manual for future reference.

Completion Time

³

1 to 3 hours.

• Proper installation is the responsibility of the installer.

Product failure due to improper installation is not

covered under the warranty. See Owner’s Manual for

warranty information.

WARNING:

This appliance must be properly grounded. Follow

directions in ”Electric Supply” of this manual. Failure to

do so may result in electric shock.
For Monogram local service in your area,

1.800.444.1845.
For Monogram Service in Canada, call 1.800.561.3344.
For Monogram Parts and Accessories, call

1.800.626.2002.
If you received a damaged range, you should contact

your dealer.
In the Commonwealth of Massachusetts:

• This product must be installed by a licensed plumber

or gas fitter.

• When using ball type gas shut off valves, they shall be

T-handle type.

• A flexible gas connector, when used, must not exceed

3 feet.

2

Installation Instructions

Vent hood Combinations:

A suitable overhead vent hood is required for models

with a grill and is recommended for all other models.

• Install a hood with at least 1200 CFM above a 48

wide

range.

• Install a hood with at least 600 CFM above a 30” or

36” range.

Due to the high heat capacity of this unit, particular

attention should be paid to the hood and ductwork

installation to assure it meets local building codes.

WARNING:

Do not install this product with an air curtain hood

or other range hood that operates by blowing air

down on the cooktop. This airflow may interfere

with operation of the gas burners resulting in fire or

explosion hazard.
Clearances to horizontal surfaces above the range,

measured to the cooking surface are below. Failure to

comply may result in fire hazard.
• Installations without a hood require 48” minimum to

combustibles.

• A custom hood installation with exposedhorizontal

combustibles surfaces must have an Auto-On

feature.

• For other installations with a hood, refer to hood

installation instructions for specific hood clearances.

CAUTION:

These ranges weigh up to 700 pounds. Some

disassembly will reduce the weight considerably. Due

to the weight and size of the range and to reduce the

risk of personal injury or damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER

INSTALLATION OF 36” AND 30” RANGES.
THREE PEOPLE ARE REQUIRED FOR PROPER

INSTALLATION OF 48” RANGES.

WARNING:

All ranges can tip. Injury could result. Install the

supplied Anti-Tip Bracket provided. See instructions

in this manual or with the bracket.

Leak testing of the appliance shall be conducted

according to the manufacturer’s instructions.
Installation must conform with local codes. In the

absence of local codes, the range must comply

with the National Fuel Gas Code, ANSIZ223.1/NFPA

54, latest edition and National Electrical Code ANSI/

NFPA 70 latest addition. In Canada, installation must

conform with the current Natural Gas Installation Code,

CAN/CGA-B149.1 or the current Propane Installation

Code, CAN/CGA-B149.2, and with local codes where

applicable. This range has been design-certified by CSA

International according to ANSI Z21.1, latest edition

and Canadian Gas Association according to CAN/CGA-

1.1 latest edition.

If sold outside the U.S. and Canada:

WARNING:

If you wish to use this product

with Liquefied Petroleum (LP) gas containing greater

than 10% butane, you must purchase the butane

conversion kit #WB28K10589. To order, please call

1.888.664.8403 or 1.787.276.4051. Failure to do so

may result in carbon monoxide or fire hazard.