POWER SUPPLY LOCATIONS

Gas Supply:

• The natural gas models are designed to operate at

5” water column pressure. For proper operation, the

pressure of the natural gas supplied to the regulator

must be between 7” and 13” water column.

• The LP models are designed to operate at 10” water

column pressure. For proper operation, the pressure

of the LP gas supplied to the regulator must be

between 11” and 13” water column.

• Locate the pipe stub on the back wall or floor as

illustrated in “Dimensions and Clearances.” Use

5-foot maximum length, 5/8” O.D. flexible gas supply

line (3-foot in Massachusetts).

9

CAUTION

Do not attempt to operate the oven if this range of

this range during a power failure.

Electric Supply:

Your range must be electrically grounded in

accordance with local codes, in accordance with

National Electrical Code (ANSI/NFPA 70, latest

edition). In Canada, electrical grounding must be in

accordance with the current CSA C22.1 Canadian

Electrical Code Part 1. See Electrical Connections in this

section.