Installation preparation, Warning, Wire power cord installation – GE ZDP364NDPSS User Manual

Page 10

Advertising
background image

Installation Preparation

4-WIRE POWER CORD INSTALLATION

NOTE: A 4-wire cord is connected to the range

at the factory. Use the following steps to change

an existing installation from a 3-wire cord back

to a 4-wire cord.

WARNING

The neutral wire of the supply circuit must be

connected to the neutral terminal located in the

lower center of the terminal block. The power

leads must be connected to the lower left and

the lower right terminals of the terminal block.

The 4th grounding lead must be connected to

the frame of the range with the ground plate

and the ground screw.
• Remove the 3 lower terminal screws from

the terminal block. Remove the ground screw

and ground plate and retain them.

Remove the ground strap. DO NOT DISCARD

THE GROUND STRAP OR ANY SCREWS.

• Insert the one ground screw into the power cord

ground wire terminal ring, through the ground

plate and into the frame of the range.

• Insert the 3 terminal screws (removed earlier)

through each power cord terminal ring and

into the lower terminals of the terminal block.

Be certain that the center wire (white/neutral)

is connected to the center lower position

of the terminal block. Tighten screws securely

into the terminal block.

Before

After

Terminal

Block

Terminal

Block

Neutral

Terminal

Neutral Terminal

Ground Strap

Ground

Plate

(grounding

to range)

Ground

Screw

Ground Strap

or

3-WIRE POWER CORD INSTALLATION

NOTE: A 4-wire cord is connected to the range

at the factory. Use the following steps to change

the range to a 3-wire cord.

WARNING

The neutral or ground wire of the power cord

must be connected to the neutral terminal located

in the center of the terminal block. The power leads

must be connected to the lower left and the lower

right terminals of the terminal block.
• Remove the ground strap (located at the right

side of the terminal block) and connect between

the center lower portion of the terminal block

to the frame of the range.

• Remove the 3 lower terminal screws from

the terminal block. Insert the 3 terminal screws

through each power cord terminal ring and

into the lower terminals of the terminal block.

Be certain that the center wire (white/neutral)

is connected to the center lower position

of the terminal block. Tighten screws securely

into the terminal block.

DO NOT remove the ground strap connection.

Ground

Strap

Terminal

Block

(appearance

may vary)

Neutral

Terminal

Power Cord

Ground

Plate

10