GE 45613 GE Z-Wave 3-Way Dimmer Kit with Terminals User Manual

Page 13

Advertising
background image

8.Connect the black wire that goes to the light to the terminal
marked LOAD.

9. Connect the black wire that comes from the electrical service
panel (Hot) to the terminal marked LINE.

Note: UL specifies that

the tightening torque for the screws is 14Kgf-cm.

10. OPTIONAL for 3 or 4-way control: Connect the Traveler
wire (usually Red) to the screw terminal marked TRAVELER.
The other end of this Traveler wire connects to the TRAVELER
screw terminal on the 45610 Auxiliary Switch. See the following
section for information about wiring the 45610 Auxiliary Switch.

11. Insert Z-Wave Switch into the switch box being careful not to
pinch or crush wires.

12. Secure the switch to the box using the supplied screws.

13. Mount the wall plate.

14. Reapply power to the circuit at fuse box or circuit breaker
and test the system.

Optional for 3 or 4-Way Control:
1. The 45610 requires the following 3 wiring connections:
a. The Traveler wire. This is used to send voltage signals to the
primary Z-Wave switch. The signals tell the Z-wave switch what
action to perform.
b. Ground.
c. Neutral.
2. DO NOT connect the 45610 auxiliary switch to the home’s black
Hot (Line) wire.

Advertising
This manual is related to the following products: