GE 45613 GE Z-Wave 3-Way Dimmer Kit with Terminals User Manual

Page 19

Advertising
background image

• Parameter 12 (timing of the steps)

• Length: 1 Byte

• Valid Values:

Parameter 11 (default = 1) Valid Values: 1-99

Parameter 12 (default = 3) Valid Values: 1-255

Ignore Start Level When Receiving Dim Commands

Please note: Every “Dim” command includes a start level

embedded in it. The 45612 can be set to ignore the start level

that is part of the dim command. Setting parameter 5 to a value

of 0 will cause the 45612 to dim or brighten from the start level

embedded in the command.

• Parameter No: 5

• Length: 1 Byte

• Valid Values = 0 or 1 (default 1)

Restoring Factory Defaults

All Configuration Parameters can all be restored to their factory default

settings by using your master controller to delete/reset the device.

WARRANTY

JASCO Products warrants this product to be free from manufacturing
defects for a period of two years from the original date of consumer
purchase. This warranty is limited to the repair or replacement of
this product only and does not extend to consequential or incidental
damage to other products that may be used with this product. This
warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts
or permit the exclusion or limitation of incidental or consequential
damage, so the above limitations may not apply to you. This warranty

Advertising
This manual is related to the following products: