Pf 3000 cotton yield monitor, Ag leader technology, System wiring – Ag Leader PF3000 Cotton Yield Monitor Operators Manual User Manual
Page 140

PF 3000 Cotton Yield Monitor
System Wiring
Ag Leader Technology
March 2002
7-6
Signal
PF3000
Cab / Distrib.
Power
Ground Spd
Fan Spd
Flow
Header
Rectangular
Round
Rectangular
Rectangular
Rectangular
Round
Rectangular
Radar
25 pin
24 pin
3 pin
2-pin
2 pin
4 pin
3 pin
4-pin
Power (14V)(US)
1
1
A
RS(485C)
2
-
RS(485A)
3
2
4
Moist2 (-)
4
3
Temp
5
4
SP1
6
5
A
SP2
7
6
A
A5V
8
7
QMinus
9
8
GND
10
9
C
1
Vcc (+5V)
11
10
A
D12V
12
11
3
Power (14V)(S)
13
12
1
RS(485B)
14
13
3
RS(485D)
15
-
Moist1 (+)
16
14
Field Marker
17
15
HDR
18
16
B
SP3
19
17
B
SP4
20
18
B
2
QPlus
21
19
AGND
22
20
GND
23
21
Vcc (+5V)
24
22
GND
25
23
C
2
Drain
shell
24