Pf3000 pro cotton yield monitor, Ag leader technology, Flow sensor alarms – Ag Leader PF3000Pro Cotton Yield Monitor Operators Manual User Manual
Page 110

PF3000 Pro Cotton Yield Monitor
Flow Sensor Alarms
Ag Leader Technology
July 2003
4-32
Introduction
The flow sensor alarms warn you when one or more flow sensors are not
operating. The types of alarms are Communications, Low Signal, Stringer
and Choke.
Alarm Activation
The activation of the alarm will be by a buzzer sounding and a full screen
message telling you which sensors are not sending data to the yield monitor.
Simply note which sensors are reporting and press the CANCEL key.
Communications
Alarm
This alarm warns you to sensors that are not operating properly resulting in
lost yield data. The example below shows sensor communication alarms for
sensors 1 and 4 for a Case-IH picker
COTTON SENSOR ERROR
ALARM CONDITION
FLOW SENSOR NOT RESPONDING
1F
4R
CHECK FLOW SENSOR
CANCEL