Control valve settings for self-propelled sprayers, Ontrol, Alve – Ag Leader EDGE Ver.4.5 Users Manual User Manual
Page 133: Ettings for, Ropelled, Prayers

121
A
PPLICATION
C
ONTROL
V
ALVE
S
ETTINGS FOR
S
ELF
-P
ROPELLED
S
PRAYERS
Control Valve Settings for Self-Propelled Sprayers
Flow Control
Valve or
Sprayer Model
(and year if
applicable)
Control System
PWM
Frequen
cy
Typical
Gain
Range
Zero
Offset
Allowabl
e Error
Valve
Respon
se
1
Valve
Respon
se
2
Respon
se
Thresho
ld
Apache
510/710/
1010/1210
(2006 and up)
In-line Servo
2%
100%
24%
Use a
starting
value of
5.* See
note
below.
All Case IH
sprayers when
using AIM
Command
AIM Command
In-line servo
2%
100%
24%
3
Case IH
Surveyor with
A-post
Non-AIM
Command
Mode PWM
12-volt
122
**700-
900
35
2%
Case IH 3320
Non-AIM
Command
Mode PWM
12-volt
122
**700-
900
35
2%
Case IH 4420
with A-post
Non-AIM
Command
Mode PWM
12-volt
122
**700-
900
35
2%
Case IH 3200
(KZKCO Valve)
Non-AIM
Command
Mode By-Pass
Servo
2%
40%
10%
5
Case IH 4260
with Raven
valve
Non-AIM
Command
Mode By-Pass
Servo
2%
100%
24%
3
Case IH 4260
with KZKCO
valve
Non-AIM
Command
Mode By-Pass
Servo
2%
40%
10%
5