Ag Leader GPS 1000 Plus to GreenStar Installation User Manual

Gps 1000 plus, Ag leader technology

Advertising
background image

GPS 1000 Plus

Installation on GreenStar™ Monitors

Ag Leader Technology

December 2003

2005638

1


Configuration
Setup


Refer to the GPS 1000 Plus General Instructions section, Using GPS 1000 Plus
Utility Version 1.1 on page 5, and install the GPS 1000 Plus utility on your
personal computer.

Step-by-Step
Procedure

1.

Double click on the GPS 1000 Plus Utility icon.

2.

Click "Connect" button

3.

Select appropriate Com Port.

4.

Verify a Baud Rate of 4800 and click the "O.K." button.

5.

Select the appropriate value under Rate column as shown below.

RATE

MESSAGE NAME

1

$GPGGA

OFF

$GPGLL

1

$GPGSA

OFF

$GPGSV

1

$GPRMC

OFF

$GPVTG

OFF

$GPZDA

6.

Baud rate setting is dependent on the firmware version used on the processor.
Set the required Baud Rate.

Firmware

Baud Rate

5.3P

9600

5.3R

4800

6.32F

4800

7.

Click "Send Configuration" button.

8.

A new screen for Serial Data should now appear.

9.

Verify the serial data strings appear beginning with:

$GPGSA……………

$GPRMC……………

$GPGGA……………

10.

If the serial data strings are incorrect repeat Steps 5 through 8.

11. Configuration is now complete. Click "Exit" button.