Ag Leader GPS 1000 Plus to GreenStar Installation User Manual
Gps 1000 plus, Ag leader technology
GPS 1000 Plus
Installation on GreenStar™ Monitors
Ag Leader Technology
December 2003
2005638
1
Configuration
Setup
Refer to the GPS 1000 Plus General Instructions section, Using GPS 1000 Plus
Utility Version 1.1 on page 5, and install the GPS 1000 Plus utility on your
personal computer.
Step-by-Step
Procedure
1.
Double click on the GPS 1000 Plus Utility icon.
2.
Click "Connect" button
3.
Select appropriate Com Port.
4.
Verify a Baud Rate of 4800 and click the "O.K." button.
5.
Select the appropriate value under Rate column as shown below.
RATE
MESSAGE NAME
1
$GPGGA
OFF
$GPGLL
1
$GPGSA
OFF
$GPGSV
1
$GPRMC
OFF
$GPVTG
OFF
$GPZDA
6.
Baud rate setting is dependent on the firmware version used on the processor.
Set the required Baud Rate.
Firmware
Baud Rate
5.3P
9600
5.3R
4800
6.32F
4800
7.
Click "Send Configuration" button.
8.
A new screen for Serial Data should now appear.
9.
Verify the serial data strings appear beginning with:
$GPGSA……………
$GPRMC……………
$GPGGA……………
10.
If the serial data strings are incorrect repeat Steps 5 through 8.