3.1 TROUBLESHOOTING (Continued)

Table 3-1. Troubleshooting Procedures (Continued).

Symptom

Malfunction

Corrective Action

2. Poor or

degraded image.

a. Battery power is low.

a. Install fresh batteries

(section 2.2).

b. Not focused for viewing

distance being observed.

b. Focus objective lens

(section 2.12).

c. Improperly adjusted

settings.

c. Reset LWTS to factory

default parameters

(section 2.8).

d. LWTS requires

calibration.

d. Perform a calibration

(section 2.19).

e. Objective lens and/or

eyepiece obscured by dirt,

dust or grime.

e. Clean objective lens and

eyepiece (section 3.2).

3. Display is on

but no thermal

image is present.

a. Objective lens cover

installed over objective

lens.

a. Flip up objective lens cover

(section 2.5).

b. Not focused for viewing

distance being observed.

b. Focus objective lens

(section 2.12).

c. Improperly adjusted

settings.

c. Reset LWTS to factory

default parameters

(section 2.8).

d. LWTS requires

calibration.

d. Perform a calibration

(section 2.19).

4. No reticle is

visible.

a. Display brightness set

too low.

a. Adjust display brightness

(section 2.21).

b. NONE reticle is

selected.

b. Ensure the 5 MIL or

M4/M16 reticle type is selected

(section 2.20).