3.3 CORRECTIVE MAINTENANCE

The LWTS

has no internal parts or assemblies replaceable

by the user or organizational level personnel. Refer to

section 3.4 regarding maintenance and/or repair actions

beyond those described in this manual.

Throw-Lever Tension Adjustment

The throw-lever mounting bracket has a locknut that adjusts

the tension required to clamp it to the weapon rail. It is

preset at the factory but may need adjustment when initially

mounted to the rail of the host weapon. If adjustment is

required, the following procedures apply and are performed

with the LWTS removed from the host weapon:

CAUTION

Creating too much tension with the locknut may

result in damage to the mounting bracket when the

throw-lever is forced against the weapon rail.

Creating too little tension with the locknut may

allow for movement of the LWTS on the rail.

Never completely remove the locknut from the

mounting bracket.

1. Swing the throw-lever closed (against the body of the

LWTS), then push in the lever lock to engage the locking

mechanism.

2. Using the provided 3/8” box wrench, adjust the locknut

using slight movements (2 or 3 degrees). Turning the

locknut counterclockwise will decrease tension on the

throw-lever. Turning it clockwise will increase tension on

the throw-lever.