Accel Enrich Fast – Acceleration enrichment fast change TPS (Throttle
Position Sensor) input. Range is 0-40.

Decel RPM – Engine RPM upper limit. If this is exceeded, the ECU to go
into the fuel cutoff mode, stopping fuel delivery.

CL On-Off – Turn the Closed Loop function On or Off.

FACTORY

DEFAULT IS “ON” – it is highly recommended to keep this function ON
for the best performance from the QFI System!

ADL – Adaptive learning feature On or Off.

FACTORY DEFAULT IS “ON”

– it is highly recommended to keep this function ON for the best
performance from the QFI System!






If you have made a mistake in SETUP or ADVANCED SETUP

, go to the CAM Type window (Step

8 in the SETUP Menu), change the setting to ANY different cam then the one you selected, PRESS
ENTER, then turn the ignition key OFF to save. Wait until the red light on the front of the ECU goes
off. Turn the key back ON, go back to the desired cam, enter it, and the system will revert to the
factory default setting. Next, proceed to the window that had the incorrect value entered, enter the
correct value, and finish the setup.