Sper Scientific 850024 Hot Wire Anemometer SD Card Logger User Manual
Page 16

16
MEASUREMENT PROCEDURES
Type K/J Thermometer
1. Press POWER to turn the meter on.
2. Press and hold FUNC to cycle through the options until
“tP” appears on the LCD. Release the FUNC button.
3. The anemometer probe must be disconnected from
the meter to obtain accurate Type K/J readings.
4. Plug a thermocouple temperature probe (type K or J)
into the type K/J thermometer socket. The LCD will
display the measurement value from the temperature
probe.
5. “K” or “J” appear on the LCD to indicate the type of
thermometer.
Note…
When using the meter for the first time, the meter will
default to K type thermocouple. See page 12 for
instructions on selecting the thermocouple type.
Hold Function
1. When measuring any parameter, press HOLD to
freeze the reading on the display. “HOLD” will appear
on the LCD.
2. Press HOLD again to release the hold function.
“HOLD” will disappear from the LCD.