Sitter, The hold button (sensor use only), Sitter elite 15 – Posey Sitter Elite® User Manual

Page 15

Advertising
background image



Sitter Elite

15

The HOLD Button (Sensor Use ONLY)

NOTE: HOLD feature will not work unless sensor is plugged into the alarm.

To Place the Alarm on HOLD:

1. Press HOLD/SUSPEND button on the top of alarm (fig. 17) for

1 second. The HOLD/SUSPEND LED will begin flashing RED

at 3-second intervals if the alarm is in HOLD mode (fig. 17a).

The green LED indicating mode will continue to flash, but the

alarm is not monitoring.

2. You have 30 seconds to assist patient into or out of bed

or chair before alarm returns to monitoring mode. When

assisting patient out of bed, move patient towards the

edge of the bed with his or her legs over the side of the

bed before pressing the HOLD button. This will allow you

more time to reposition the patient on the sensor without

activating the alarm after the 30 second HOLD period expires.

3. After 30 seconds:

• If weight is present on the sensor, or chair belt sensor is

connected you will hear a single “beep” and monitoring

will begin.

ALWAYS verify the green light is flashing, and

the alarm and sensors are monitoring before leaving patient

unattended.

• If there is no weight on sensor, or chair belt sensor is not

connected, alarm will remain on HOLD.

4. The HOLD feature:

• Allows patient to be away from bed or chair for extended

periods without alarm activating (e.g., for meals, therapy,

toileting etc.). When patient returns and weight is applied to

sensor or chair belt sensor is connected, alarm will “beep” once to indicate monitoring has

resumed. The red LED below HOLD/SUSPEND will no longer be flashing.

• Helps ensure continuity of care when there are several caregivers.

5. To take alarm out of HOLD:

• Apply weight to sensor, or connect chair belt sensor; or

• Press HOLD button once.

Alarm will “beep” once to indicate monitoring has resumed.
Flashing red HOLD/SUSPEND LED will no longer be flashing. The green light indicating

mode will blink, indicating the alarm is in monitoring mode.

Test the alarm and sensor for proper operation prior to putting in service with

a patient, and each time before leaving the patient unattended. If the alarm and/or sensor

do not function properly, remove the alarm and sensor from service and replace them with a

properly functioning alarm and/or sensor (see pages 22-24). Ensure the green LED, indicating

MODE, is blinking and the red HOLD/SUSPEND LED is no longer flashing red.

VOICE

&

TONE

TONE

MUTE

VOICE

NURSE C

ALL

MIC

HOLD

&

SUSPEND

HOLD/SUSP

END

HOLD/SUSPEND Button

Fig. 17

H O L D / S U S P E N D

®

Sitter

HOLD/SUSPEND

Indicator LED

Fig. 17a

Advertising