Eneral, Eter, Pecifications – Red Lion CUB5T User Manual

Page 2: Rdering, Nformation

Advertising
background image

1. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits

CUB5TR00: Reflective LCD with full viewing angle
CUB5TB00: Selectable transmissive red or green backlight LED with
viewing angle optimized. Display color change capability at preset when
using a relay module.

2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input

polarity protection. Must use an RLC model MLPS or a Class 2 or SELV
rated power supply.

3. TIMER DISPLAY: 7-digits

Display Designator: “

t

” to the left side of the display

Display Range: 0 to 9999999
Overflow/Underflow Indication: Display flashes “

t OVEr

Minimum Digit Resolution: 0.001 Sec.
Maximum Single Digit Resolution: 1 Hr.
Timing Accuracy: ±0.01%

4. CYCLE COUNTER DISPLAY: 6-digits, may be disabled if not used

Display Designator: “

C

” to the left side of the display

Display Range: 0 to 999999
Overflow/Underflow Indication: Display flashes “

C OVEr

Maximum Count Rate:

All Count Sources except Input B: 10 Hz
Input B Count Source:

With Timer Input Filter ON: 10 Hz
With Timer Input Filter OFF: 500 Hz

5. TIMER SIGNAL INPUTS (INP A and INP B)

Logic Inputs, Current Sinking (active low)

Input A:

Internal 7.8K

 pull-up resistor to +9 to 28 VDC

Trigger levels: V

IL

= 1.25 V max; V

IH

= 2.75 V min; V

MAX

= 28 VDC

Input B:

Internal 10K

 pull-up resistor to +9 to 28 VDC

Trigger levels: V

IL

= 0.7 V max; V

IH

= 2.4 V min; V

MAX

= 28 VDC

Inputs A and B:

Timer Input Pulse Width: 1 msec min.
Timer Start/Stop Response Time: 1 msec max.
Filter: Software filtering provided for relay or switch contact debounce.

Filter enabled or disabled through programming. If enabled, results in
50 msec start/stop response time for successive pulses applied to the
same input terminal.

6. USER INPUT (USR): Programmable function input

Logic Input, Current Sinking (active low)
Internal 10K

 pull-up resistor to +9 to 28 VDC

Trigger levels: V

IL

= 0.7 V max; V

IH

= 2.4 V min; V

MAX

= 28 VDC

Response Time: 5 msec typ.; 50 msec debounce (activation and release)

7. MEMORY: Nonvolatile E

2

PROM memory retains all programming

parameters and timer/counter values when power is removed.

8. CONNECTIONS: Wire clamping screw terminals

Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.

9. ENVIRONMENTAL CONDITIONS:

Operating Temperature Range for CUB5TR00: -35 to 75°C
Operating Temperature Range for CUB5TB00 depends on display color

and intensity level as per below:

INTENSITY LEVEL

TEMPERATURE

Red Display

1 & 2

-35 to 75°C

3

-35 to 70°C

4

-35 to 60°C

5

-35 to 50°C

Green Display

1 & 2

-35 to 75°C

3

-35 to 65°C

4

-35 to 50°C

5

-35 to 35°C

Storage Temperature: -35 to 85°C

Operating and Storage Humidity: 0 to 85% max. relative humidity (non-

condensing)

Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z

direction for 1.5 hours, 5 g.

Shock According to IEC 68-2-27: Operational 40 g, 11 msec in 3 directions.
Altitude: Up to 2000 meters

10. CERTIFICATIONS AND COMPLIANCES:

SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA 22.2 No. 61010-1

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Outdoor Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report #E179259-V01-S02

Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.

Notes:
1. Criterion A: Normal operation within specified limits.

Refer to EMC Installation Guidelines for additional information.

11. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for

outdoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.

12. WEIGHT: 3.2 oz (100 g)

2

G

ENERAL

M

ETER

S

PECIFICATIONS

O

RDERING

I

NFORMATION

MODEL

NUMBER

DISPLAY COLOR

INPUT CURRENT

WITHOUT

CUB5RLY0

INPUT CURRENT

WITH

CUB5RLY0

CUB5TR00

---

10 mA

30 mA

CUB5TB00

Red (max intensity)

85 mA

115 mA

CUB5TB00

Green (max intensity)

95 mA

125 mA

Class A

EN 55011

Emissions

Emissions:

30 A/m

3 V/rms
Criterion A

Criterion A

EN 61000-4-8

EN 61000-4-6

RF conducted interference

1 kV L-L,

Criterion A

EN 61000-4-5

Surge

1 kV signal

2 kV power

Criterion A

EN 61000-4-4

Fast transients (burst)

2 kV L&N-E power

10 V/m

Criterion A

EN 61000-4-3

Electromagnetic RF fields

8 kV air discharge

4 kV contact discharge

Criterion A

EN 61000-4-2

Electrostatic discharge

Immunity to Industrial Locations:

Power frequency magnetic fields

TYPE

MODEL NO.

DESCRIPTION

PART NUMBER

CUB5

CUB5TR

Preset Timer and Cycle Counter with Reflective Display

CUB5TR00

CUB5TB

Preset Timer and Cycle Counter with Backlight Display

CUB5TB00

Optional Plug-in Cards

CUB5RLY

Single Relay Option Card

CUB5RLY0

CUB5COM

RS485 Serial Communications Card

CUB5COM1

RS232 Serial Communications Card

CUB5COM2

Accessories

MLPS

+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out

MLPS1000

+24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out

MLPS2000

CBLPROG

Programming Cable RS232 (RJ11-DB9)

CBLPROG0

CBPRO

Programming Cable RS485 (RJ11-DB9)

CBPRO007

Advertising