1. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits
CUB5TR00: Reflective LCD with full viewing angle
CUB5TB00: Selectable transmissive red or green backlight LED with
viewing angle optimized. Display color change capability at preset when
using a relay module.
2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input
polarity protection. Must use an RLC model MLPS or a Class 2 or SELV
rated power supply.
3. TIMER DISPLAY: 7-digits
Display Designator: “
t
” to the left side of the display
Display Range: 0 to 9999999
Overflow/Underflow Indication: Display flashes “
t OVEr
”
Minimum Digit Resolution: 0.001 Sec.
Maximum Single Digit Resolution: 1 Hr.
Timing Accuracy: ±0.01%
4. CYCLE COUNTER DISPLAY: 6-digits, may be disabled if not used
Display Designator: “
C
” to the left side of the display
Display Range: 0 to 999999
Overflow/Underflow Indication: Display flashes “
C OVEr
”
Maximum Count Rate:
All Count Sources except Input B: 10 Hz
Input B Count Source:
With Timer Input Filter ON: 10 Hz
With Timer Input Filter OFF: 500 Hz
5. TIMER SIGNAL INPUTS (INP A and INP B)
Logic Inputs, Current Sinking (active low)
Input A:
Internal 7.8K
pull-up resistor to +9 to 28 VDC
Trigger levels: V
IL
= 1.25 V max; V
IH
= 2.75 V min; V
MAX
= 28 VDC
Input B:
Internal 10K
pull-up resistor to +9 to 28 VDC
Trigger levels: V
IL
= 0.7 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Inputs A and B:
Timer Input Pulse Width: 1 msec min.
Timer Start/Stop Response Time: 1 msec max.
Filter: Software filtering provided for relay or switch contact debounce.
Filter enabled or disabled through programming. If enabled, results in
50 msec start/stop response time for successive pulses applied to the
same input terminal.
6. USER INPUT (USR): Programmable function input
Logic Input, Current Sinking (active low)
Internal 10K
pull-up resistor to +9 to 28 VDC
Trigger levels: V
IL
= 0.7 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Response Time: 5 msec typ.; 50 msec debounce (activation and release)
7. MEMORY: Nonvolatile E
2
PROM memory retains all programming
parameters and timer/counter values when power is removed.
8. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.
9. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5TR00: -35 to 75°C
Operating Temperature Range for CUB5TB00 depends on display color
and intensity level as per below:
INTENSITY LEVEL
TEMPERATURE
Red Display
1 & 2
-35 to 75°C
3
-35 to 70°C
4
-35 to 60°C
5
-35 to 50°C
Green Display
1 & 2
-35 to 75°C
3
-35 to 65°C
4
-35 to 50°C
5
-35 to 35°C
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-
condensing)
Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z
direction for 1.5 hours, 5 g.
Shock According to IEC 68-2-27: Operational 40 g, 11 msec in 3 directions.
Altitude: Up to 2000 meters
10. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA 22.2 No. 61010-1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Outdoor Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report #E179259-V01-S02
Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
Notes:
1. Criterion A: Normal operation within specified limits.
Refer to EMC Installation Guidelines for additional information.
11. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for
outdoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.
12. WEIGHT: 3.2 oz (100 g)
2
G
ENERAL
M
ETER
S
PECIFICATIONS
O
RDERING
I
NFORMATION
MODEL
NUMBER
DISPLAY COLOR
INPUT CURRENT
WITHOUT
CUB5RLY0
INPUT CURRENT
WITH
CUB5RLY0
CUB5TR00
---
10 mA
30 mA
CUB5TB00
Red (max intensity)
85 mA
115 mA
CUB5TB00
Green (max intensity)
95 mA
125 mA
Class A
EN 55011
Emissions
Emissions:
30 A/m
3 V/rms
Criterion A
Criterion A
EN 61000-4-8
EN 61000-4-6
RF conducted interference
1 kV L-L,
Criterion A
EN 61000-4-5
Surge
1 kV signal
2 kV power
Criterion A
EN 61000-4-4
Fast transients (burst)
2 kV L&N-E power
10 V/m
Criterion A
EN 61000-4-3
Electromagnetic RF fields
8 kV air discharge
4 kV contact discharge
Criterion A
EN 61000-4-2
Electrostatic discharge
Immunity to Industrial Locations:
Power frequency magnetic fields
TYPE
MODEL NO.
DESCRIPTION
PART NUMBER
CUB5
CUB5TR
Preset Timer and Cycle Counter with Reflective Display
CUB5TR00
CUB5TB
Preset Timer and Cycle Counter with Backlight Display
CUB5TB00
Optional Plug-in Cards
CUB5RLY
Single Relay Option Card
CUB5RLY0
CUB5COM
RS485 Serial Communications Card
CUB5COM1
RS232 Serial Communications Card
CUB5COM2
Accessories
MLPS
+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out
MLPS1000
+24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out
MLPS2000
CBLPROG
Programming Cable RS232 (RJ11-DB9)
CBLPROG0
CBPRO
Programming Cable RS485 (RJ11-DB9)
CBPRO007