PROGRAMMING MODE ENTRY (SEL KEY)

It is recommended all programming changes be made off line, or before

installation. The meter normally operates in the Display Mode. No parameters
can be programmed in this mode. The Programming Mode is entered by
pressing and holding the

SEL

key. If it is not accessible, then it is locked by

either a security code, or a hardware lock (See Module 3).

MODULE ENTRY (SEL & RST KEYS)

The Programming Menu is organized into separate modules. These modules

group together parameters that are related in function. The display will alternate
between



and the present module. The

RST

key is used to select the desired

module. The displayed module is entered by pressing the

SEL

key.

MODULE MENU (SEL KEY)

Each module has a separate module menu (which is shown at the start of each

module discussion). The

SEL

key is pressed to advance to a particular parameter

to be changed, without changing the programming of preceding parameters.
After completing a module, the display will return to

 

. Programming

may continue by accessing additional modules.

SELECTION / VALUE ENTRY

For each parameter, the display alternates between the present parameter and

the selections/value for that parameter. The

RST

key is used to move through the

selections/values for that parameter. Pressing the

SEL

key, stores and activates the

displayed selection/value. This also advances the meter to the next parameter.

For numeric values, press the

RST

key to access the value. The right hand

most digit will begin to flash. Pressing the

RST

key again increments the digit

by one or the user can hold the

RST

key and the digit will automatically scroll.

The

SEL

key will advance to the next digit. Pressing and holding the

SEL

key

will enter the value and move to the next parameter.

PROGRAMMING MODE EXIT (SEL KEY)

The Programming Mode is exited by pressing the

SEL

key with



displayed. This will commit any stored parameter changes to memory and
return the meter to the Display Mode. (If power loss occurs before returning to
the Display Mode, verify recent parameter changes.)

PROGRAMMING TIPS

It is recommended to start with Module 1 and proceed through each module

in sequence. When programming is complete, it is recommended to record the
parameter programming and lock out parameter programming with the user
input or programming security code.

FACTORY SETTINGS

Factory Settings may be completely restored in Module 3. This is useful

when encountering programming problems.

Pressing the

RST

key on power-up will load the factory settings and display

rESEt

. This allows operation in the event of a memory failure or corrupted data.

ALTERNATING SELECTION DISPLAY

In the explanation of the modules, the following dual display with arrows will

appear. This is used to illustrate the display alternating between the parameter
on top and the parameter’s Factory Setting on the bottom. In most cases,
selections and values for the parameter will be listed on the right.

6.0 P

ROGRAMMING

THE

M

ETER

Setpoint

Output

Parameters

Timer Input

Parameters

Pro

DISPLAY

MODE

Cycle Counter

Parameters

3-dSPLAY

Display and Front

Panel Key

Parameters

NO

SEL

RST

SEL

SEL

SEL

SEL

2-Count

1-INPUt

4-SEtPt

5-SEriAL

SEL

Serial
Setup

Parameters

OVERVIEW

PROGRAMMING MENU

Indicates Program Mode Alternating Display

Factory Settings are shown.

Parameter

Selection/Value

LEVEL

INPUt

s

OP

5.0 R

EVIEWING

THE

F

RONT

B

UTTONS

AND

D

ISPLAY

SEL

RST

1

KEY

DISPLAY MODE OPERATION

ENTERING PROGRAM MODE

PROGRAMMING MODE OPERATION

SEL

Select display (timer or cycle counter)

Press and hold for 2 seconds to activate

Store selected parameter and index to next parameter

RST

Reset value(s) per Front Panel Reset setting

Advances through the program menu
Increments selected parameter value or selection

OPERATING MODE DISPLAY DESIGNATORS

t

- To the left of the display is the timer value.

C

- To the left of the display is the cycle counter value.

“1” - To the upper left of the display indicates the setpoint status.

If display scroll is enabled, the display will toggle automatically every four seconds between the timer and cycle counter values.