Rogramming, Eter, Level input – Red Lion CUB5T User Manual
Page 6: Eviewing, Ront, Uttons, Isplay, Overview, Dsplay, Count 1-input 4-setpt 5-serial
![background image](/manuals/408933/6/background.png)
6
PROGRAMMING MODE ENTRY (SEL KEY)
It is recommended all programming changes be made off line, or before
installation. The meter normally operates in the Display Mode. No parameters
can be programmed in this mode. The Programming Mode is entered by
pressing and holding the
SEL
key. If it is not accessible, then it is locked by
either a security code, or a hardware lock (See Module 3).
MODULE ENTRY (SEL & RST KEYS)
The Programming Menu is organized into separate modules. These modules
group together parameters that are related in function. The display will alternate
between
and the present module. The
RST
key is used to select the desired
module. The displayed module is entered by pressing the
SEL
key.
MODULE MENU (SEL KEY)
Each module has a separate module menu (which is shown at the start of each
module discussion). The
SEL
key is pressed to advance to a particular parameter
to be changed, without changing the programming of preceding parameters.
After completing a module, the display will return to
. Programming
may continue by accessing additional modules.
SELECTION / VALUE ENTRY
For each parameter, the display alternates between the present parameter and
the selections/value for that parameter. The
RST
key is used to move through the
selections/values for that parameter. Pressing the
SEL
key, stores and activates the
displayed selection/value. This also advances the meter to the next parameter.
For numeric values, press the
RST
key to access the value. The right hand
most digit will begin to flash. Pressing the
RST
key again increments the digit
by one or the user can hold the
RST
key and the digit will automatically scroll.
The
SEL
key will advance to the next digit. Pressing and holding the
SEL
key
will enter the value and move to the next parameter.
PROGRAMMING MODE EXIT (SEL KEY)
The Programming Mode is exited by pressing the
SEL
key with
displayed. This will commit any stored parameter changes to memory and
return the meter to the Display Mode. (If power loss occurs before returning to
the Display Mode, verify recent parameter changes.)
PROGRAMMING TIPS
It is recommended to start with Module 1 and proceed through each module
in sequence. When programming is complete, it is recommended to record the
parameter programming and lock out parameter programming with the user
input or programming security code.
FACTORY SETTINGS
Factory Settings may be completely restored in Module 3. This is useful
when encountering programming problems.
Pressing the
RST
key on power-up will load the factory settings and display
rESEt
. This allows operation in the event of a memory failure or corrupted data.
ALTERNATING SELECTION DISPLAY
In the explanation of the modules, the following dual display with arrows will
appear. This is used to illustrate the display alternating between the parameter
on top and the parameter’s Factory Setting on the bottom. In most cases,
selections and values for the parameter will be listed on the right.
6.0 P
ROGRAMMING
THE
M
ETER
Setpoint
Output
Parameters
Timer Input
Parameters
Pro
DISPLAY
MODE
Cycle Counter
Parameters
3-dSPLAY
Display and Front
Panel Key
Parameters
NO
SEL
RST
SEL
SEL
SEL
SEL
2-Count
1-INPUt
4-SEtPt
5-SEriAL
SEL
Serial
Setup
Parameters
OVERVIEW
PROGRAMMING MENU
Indicates Program Mode Alternating Display
Factory Settings are shown.
Parameter
Selection/Value
LEVEL
INPUt
s
OP
5.0 R
EVIEWING
THE
F
RONT
B
UTTONS
AND
D
ISPLAY
SEL
RST
1
KEY
DISPLAY MODE OPERATION
ENTERING PROGRAM MODE
PROGRAMMING MODE OPERATION
SEL
Select display (timer or cycle counter)
Press and hold for 2 seconds to activate
Store selected parameter and index to next parameter
RST
Reset value(s) per Front Panel Reset setting
Advances through the program menu
Increments selected parameter value or selection
OPERATING MODE DISPLAY DESIGNATORS
“
t
”
- To the left of the display is the timer value.
“
C
”
- To the left of the display is the cycle counter value.
“1” - To the upper left of the display indicates the setpoint status.
If display scroll is enabled, the display will toggle automatically every four seconds between the timer and cycle counter values.