6.2 DVC61 Screens

Each DVC61 device can support multiple screen images to
display information in various forms.

Each device has up to 12 display variables available to each
screen. At run time each variable can be assigned the value
of an input or output program variable or another variable.

Every screen image has fields to specify its Name, define
which of the 12 display variables will be displayed, the X, Y
location for the variable and in what format. You may also
enter fixed textual information for the image. A shaded area
to allow the user to preview the finished screen image with
sample variable values is provided.

Name:
The name used in the bubble logic to access this screen and its properties.
Range: 16 alpha/numeric characters only with no spaces.
Rules: The first character cannot be a number, compiler keyword or another names already being used. Usable
characters are A-Z, a-z, 0-9, and "_".

V1, … ,V12:
Scroll down list of display types/formats
Refer to Section 8.2 for an explanation of Display Types.

X & Y These are the X and Y numeric text character position and line coordinates for the Display

variables. The Upper left corner is X = 1 and Y = 1.


Test Value This is the value displayed on the test screen to allow the user to preview the finished screen while

in the programming tool.


DVC61 Program Variables
Note: “DVC61” in the examples below is the default device name but could be another name of your choosing.

DVC61.Screen

Identifies the screen image to be displayed

DVC61.V1

Get/Set the value for the V1.

Range: 0 to 65535

DVC61.V2

Get/Set the value for the V2.

Range: 0 to 65535

DVC61.V3

Get/Set the value for the V3.

Range: 0 to 65535

******
DVC61.V12

Get/Set the value for the V12

Range: 0 to 65535

DVC61.Backlight

Get/Set The value of the Backlight.

Range: 0 to 1023

DVC61.Contrast

Get/Set The value of the Contrast Level.
Range: 0 to 1023

DVC61.Status

Get the state of the flag.
Range: False = Module is Online, True = Module is Offline