11 add device net module, Add device net module – High Country Tek DVC80 User Manual

Page 104

Advertising
background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 104

Engine Oil Pressure

254, 239

65263

FEEF

4

1

4

kPa/bit

0

Coolant Pressure

254, 239

65263

FEEF

7

1

2

kPa/bit

0

Level /
Pressure

Coolant Level

254, 239

65263

FEEF

8

1

0.4

%/bit

0

Cruise
Control/
Vehicle
Speed

Wheel Based Vehicle Speed

254, 241

65265

FEF1

2

2

1/256

Km/h/bit

0

Fuel Rate

254, 242

65266

FEF2

1

2

0.05

L/h/bit

0

Instantaneous Fuel Economy

254, 242 65266 FEF2

3 2

1/512

km/L/bit

0

Fuel
Economy

Average Fuel Economy

254, 242

65266 FEF2

5 2

1/512

km/L/bit

0

Barometric Pressure

254, 245

65269

FEF5

1

1

0.5

kPa/bit

0

Ambient
Condition
s

Air Inlet Temperature

254, 245

65269

FEF5

6

1

1

C/bit

-40

Boost Pressure

254, 246

65270

FEF6

2

1

2

kPa/bit

0

Intake Manifold Temp

254, 246

65270

FEF6

3

1

1

C/bit

-40

Air Filter Differential Pressure

254, 246

65270

FEF6

5

1

0.05

kPa/bit

0

Inlet/Exha
ust
Condition
s

Exhaust Gas Temperature

254, 246

65270

FEF6

6

2

0.0312
5

C/bit -273

Electrical Potential (Voltage)

254, 247

65271

FEF7

5

2

0.05

V/bit

0

Vehicle
Electrical
Power

Battery Pot. Voltage
(Switched)

254, 247

65271

FEF7

7

2

0.05

V/bit

0

Transmission Oil Pressure

254, 248

65272

FEF8

4

1

16

kPa/bit

0

Transmis
son
Fluids

Transmission Oil Temperature

254, 248

65272

FEF8

5

2

0.0312
5

C/bit -273

Injector Metering Rail 1 Pres

254, 219 65243 FEDB

3 2

1/256

MPa/bit

0

Engine
Fluid
Level/Pre
ssure

Injector Metering Rail2 Pres

254, 219 65243 FEDB

7 2

1/256

MPa/bit

0

6.11

Add Device Net Module


Communication between a DVC5/7/10 Master controller
and a CAN Bus Device Net module is possible using the
Programming Tool. To communicate with a CAN Bus
Device Net device first add a DNET icon into your
project by right clicking in the project window and
selecting the Add Device Net module option from the
popup menu. Next, double click the DNET icon to bring
up the Device Net module window as shown. Using this
window you define the variable names used to send or
receive information from the Device Net module with the
specified MAC ID.

A brief explanation follows that will help explain how
communication is accomplished between the DVC5/7/10
and a Device Net module. The DVC BIOS uses the
explicit message feature of the Device Net protocol.
Each CAN Bus message has an eight byte data field. The first byte of which is the explicit message header.
The other 7 bytes contain the actual data. Messages of more than 7 bytes will take multiple messages to be
transmitted. Each message uses the header to identify the part of the message being received. Your
application will not see the header byte but will have to assemble multiple bytes into application variables where
needed.

Within the Device Net Module window are several fields. The Name field identifies the device. It is the prefix to
reference consume and produce variables. The MAC ID field represents the CAN Bus identifier for the device.