15 dvc61 (display module) and the loader monitor, Dvc61 (display module) and the loader monitor – High Country Tek DVC80 User Manual

Page 126

Advertising
background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 126

7.15

DVC61 (Display Module) and the Loader Monitor

The following screen appears when connected directly to
the DVC61. This screen enables the user to monitor the
status of the Inputs, Baud rate, Supply Voltage, Serial
Number and MAC ID as well as changing some of the
features of the DVC61. When viewing this screen while
connected to the DVC5/710 certain features will be “grayed
out” because changes cannot be sent to the DVC61
through the DVC5/7/10.

MAC ID
This setting is used to set the modules address for
communication on the CAN Bus. Possible values range from 0 to 63 and the user must select “Send Changes”
to invoke a change.

Caution: If the MAC ID is changed to a value different from that in the Programming Tool’s DVC61 configuration
screen and the Send Changes button is pressed, the new value will be saved to temporary memory. If the
DVC7/10 is plugged in, it will not recognize or be able to communicate with the DVC61 until the application is
changed and reloaded onto the DVC7/10.

Baud Rate
This pull down menu is used to select between different CAN Bus communication rates. Possible values are
125Kps, 250Kps and 500Kps, the user must select “Send Changes” to invoke a change.

Caution: If the baud rate is changed to a value different than the rate in use by the DVC7/10 and the Send
Changes button is pressed, the new value will be saved to temporary memory. If the DVC7/10 is plugged in, it
will not be able to communicate with the DVC61 until its baud rate is changed to match that of the DVC61 using
the Program Loader Monitor factory info window.

Default LCD Contrast / Backlight
Changing these settings and selecting “Send Changes” will reset the default values for Contrast and Backlight
levels for this unit.

Default Screen / Blank Screen
This pull down menu is used to select between the “High Country Tek” default screen and a “Blank” screen to be
displayed at power up until the application writes its own screen to the display module. The user must select
“Send Changes” to invoke a change.

CAN Terminating Resistor On / Off
This pull down menu is used to set whether the internal CAN Bus terminating resistor is active or not. The user
must select “Send Changes” to invoke a change.

Display Screen (Button)
This switch allows the user to toggle between monitoring the unit’s settings and monitoring the current screen
being displayed by the application.



Advertising
This manual is related to the following products: