7.16

DVC70 (Logging Module) and the Loader Monitor



This screen appears when you monitor the
DVC70 through the DVC7/10. The window is a
status display and to change settings or
download accumulated data you will need to
connect the Program Loader Monitor directly to
the DVC70.










The following screen appears when connected
directly to a DVC70. This screen enables
monitoring of Memory bucket space and the
download of data from the DVC70 to your PC.

Features of the DVC70 Program Loader Monitor
screen are:
Alarm Warning will be shown when a certain
percentage of the Memory bucket or Allocation
block memory being viewed has been filled with
data. This depends on the settings chosen by the
user during set up using the Programming Tool.
Active Warning means that the DVC70 is in the
process of logging data.

Extract button – this button extracts all the data for
the selected Allocation Block or Memory bucket.
The data is then processed and saved to a “.CSV” file. The CSV file can be viewed using MS Excel.
Erase button – this button erases all the data present in the selected Allocation Block.
Set to PC time button – this button sets the DVC70 to the same time displayed in the user’s PC.
Extract and Erase All button – this button extracts and erases all the data present in the DVC70 from all
Allocation Blocks.
Format DVC70 button – this button erases the present Profile in the DVC70. This should be done when the
data being logged has been changed in the Programming Tool. The new Profile reflecting the changes is then
activated.
Allocation Block Selection – this slide ‘bar’ allows the user to choose from amongst the 5 possible Allocation
Blocks/Memory buckets.

Memory Used Indicator – this indicator shows both a graphical as well as a percent number which reflect how
much of the selected Allocation Block has been used for data logging.