Input/output functions – High Country Tek DVC80 User Manual

Page 54

Advertising
background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 54

Name.ProI

Process Proportional Term Constant “I”

0 – 255

Name.ProItime

Update / Integration Time

0.0 to 650.00 s

Name.Cur

Current actual * CurGain = amps

0 – 3.5 amps

Name.RampCur

Current ramped Currend*CurGain= amps

0 – 3.5 amps

Name.CurErr

Current Error = RampCur – Cur

16 bit signed integer

Name.CurSumErr

Current Error accumulated over time

0 – 65535

Name.CurP

Current Proportional Term Constant “P”

0 – 255

Name.CurI

Current Proportional Term Constant “I”

0 – 255

Name.MinCurA

Minimum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MaxCurA

Maximum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MinCurB

Minimum Current Coil B *.001 = amps

0 – 3.5 amps

Name.MaxCurB

Maximum Current Coil B *.001 = amps

0 – 3.5 amps

Name.Config

Configuration Word – Output, Process,
Coil

Status LED

Name Description

Range

BlinkCode

The Status LED blinks the amount of times equal to the number
written to this location. When the blinking is done, the value for this
location will be 0.

0 to 65535


Input/Output Functions

Name Description

Range

Name.In

Changing this variable will update the "Name.Out"
variable by the BIOS after a delay of 10ms

0% to 100%

Name.Out

The Output of the Transfer Function

0% to 100%

Name.X0

The X0 of the input/output function

0% to 100%

Name.X1

The X1 of the input/output function

0% to 100%

Name.X2

The X2 of the input/output function

0% to 100%

Name.X3

The X3 of the input/output function

0% to 100%

Name.X4

The X4 of the input/output function

0% to 100%

Name.X5

The X5 of the input/output function

0% to 100%

Name.X6

The X6 of the input/output function

0% to 100%

Name.X7

The X7 of the input/output function

0% to 100%

Name.Y0

The Y0 of the input/output function

0% to 100%

Name.Y1

The Y1 of the input/output function

0% to 100%

Name.Y2

The Y2 of the input/output function

0% to 100%

Name.Y3

The Y3 of the input/output function

0% to 100%

Name.Y4

The Y4 of the input/output function

0% to 100%

Name.Y5

The Y5 of the input/output function

0% to 100%

Name.Y6

The Y6 of the input/output function

0% to 100%

Name.Y7

The Y7 of the input/output function

0% to 100%


Power Supply

Name

Description

Supply

The Power Supply voltage. The value returned is in units of supply volts (sv)


Temperature

Name

Description

DVC_Temperature Internal DVC5/7 controller temperature. The value returned is in units of

degrees C + 40. Therefore, –40 C is returned as 0.