Packet-2 data band, Com port speed, Using external tnc – Kenwood TM-D710GA User Manual

Page 40

Advertising
background image

PACKET-2

DATA BAND

Select how data will be transmitted and received on your
transceiver.

1 Enter Menu mode and access Menu 930.

2 Set the data band to A-BAND (A band receives and

transmits), B-BAND (B band receives and transmits), TX:A-
BAND RX:B-BAND (A band transmits (

) and B band

receives (

)), or RX:A-BAND TX:B-BAND (A band receives

(

) and B band transmits (

)).

COM PORT SPEED

You can adjust the speed at which the computer and transceiver
exchange information, when the transceiver is connected to your
computer.

1 Enter Menu mode and access Menu 929.

2 Set the COM port speed to 9600, 19200, 38400, or 57600

bps.

Turning the power ON/OFF will change the port speed setting.

USING EXTERNAL TNC

External Data Band

1 Enter Menu mode and access Menu 918.

2 Set the data band to A-BAND (A band receives and

transmits), B-BAND (B band receives and transmits),
TX:A-BAND RX:B-BAND (A band transmits and B band
receives), or RX:A-BAND TX:B-BAND (A band receives
and B band transmits).

DATA Terminal Speed

Select 1200 or 9600 bps for the data transfer rate, depending
on TNC.

1200

bps: Transmit data input (PKD) sensitivity is 40 mV

p-p

,

and input impedance is 10 k

.

9600

bps: Transmit data input (PKD) sensitivity is 2 V

p-p

, and

input impedance is 10 k

.

1 Enter Menu mode and access Menu 919.

2 Set the data speed to 1200 or 9600 bps.

SQC Output Setting

You can set the condition for which the SQC output terminal
becomes active.

1 Enter Menu mode and access Menu 921.

2 Set the SQC output activation method to one of the

following:

OFF: SQC output remains inactive.

BUSY: When a signal is received on the data band, the SQC
output becomes active.

SQL: While CTCSS/DCS is ON and a matching signal is
received, the SQC output becomes active. While CTCSS/
DCS is OFF, the SQC output becomes active when a busy
signal is received.

TX: While transmitting, the SQC output becomes active.

BUSY.TX: When the conditions of BUSY and TX (above) are
met, the SQC output becomes active.

SQL.TX: When the conditions of SQL and TX (above) are
met, the SQC output becomes active.

Note: The activation type (logic) can be changed using the MCP-6A
software ([Edit] - [Data Terminal] - [SQC Output Logic]).